SS510 D 200BL Broadband Transducer
Airmar’s patented SS510 reflects a strong commitment to innovation, delivering high-resolution performance in shallow-water environments. Operating at 200 kHz with an exceptionally low Q of 2, this broadband transducer offers excellent sensitivity for accurate, detailed surveying. The SS510 is also Chirp-capable, supporting long pulse transmissions across a wide frequency band. When paired with adjustable-frequency echosounders, users can fine-tune the operating frequency and beamwidth to match specific survey conditions, maximizing clarity and adaptability in the field. For added convenience, the threaded stem allows for quick, portable mounting, making it ideal for temporary installations or versatile fieldwork.
FEATURES
- Broadband with low Q of 2
- Minimal sidelobes for concentrated energy on target, providing excellent definition
- Internal transformer provides impedance match to echosounder and allows use of longer cable
- 500 W RMS, power rating is at 2% duty cycle
- Short, threaded stem simplifies attaching to portable-mounting apparatus
Robust, stainless-steel housing
- Exclusive Xducer ID® technology
SPECIFICATIONS
- Acoustic Window: Urethane
- Applications: Bridge scour inspection systems, Portable hydrographic survey, Dredging, River/estuary/harbor survey
- Beam Angle: 8°
- Cable Type: C33, one shielded twisted pair (2-20 AWG) with braided shield, black neoprene jacket, 6 mm (17/64") diameter
- Cable-Length: Various lengths offered, Maximum 20 m (65')
- CE Certification: Marine standard IEC60945
- Current Draw: 150 mA @ 12 V for 200 kHz
- Data Output: Analog
- Depth Accuracy: 99.46% at full range (see accuracy table for more info)
- Depth Display Resolution: 1 cm (.40")
- Flash Reprogrammability: Using boot loader with encryption
- Full Auto Mode Data Output Rate: From 0.1 to 25 sec/interval
- Housing Depth Rating: Submersible to 10 m (33')
- Housing Type: SS510
- Manual Mode: Output rate equal to ping rate
- Maximum Depth Reading: 200 m (656'), limited in manual mode
- Minimum Depth Reading: 0.4 m (15.75"), limited in manual mode
- Mounting: Pole mount capable for portable installations
- Operating Temp Range: -5C to +60C
- Power and Data Cable: ER SS510: C304, 4 twisted pairs with TPR jacket
- Power Supply Voltage: 9 to 40 VDC, Regulated
- Reverse Polarity Protection: Yes
- Signal Type: Analog
- Stem Thread: 1/2"-14 NPS
- Storage Temperature Range: -30 to 70°C (-22 to 158°F)
- Weight: 1.3 kg (2.8 lb.)